tidal volume, inspiratory time and positive end expiratory pressure were kept constant between changing from pressure controlled to volume controlled mode or vice versa for twenty minutes in order to allow adequate time for equilibration.

describe mechanical dead space ventilation

The mechanical ventilator (Benett 7200 or Servo 900C) setting during VD measurement i.e. From November 1996 to March 1997, 12 patients who were admitted to the pediatric intensive care unit and needed ventilator support for various reasons, were enrolled in the study. The objective of this study was to measure and compare the dead space in pediatric patients who were using pressure controlled and volume controlled modes of mechanical ventilatory by measuring the difference between arterial PCO2 and end-tidal PCO2. However, VD is not constant and can change according to the pathology in the lungs, ventilatory patterns, perfusion and ventilation-perfusion matching. Dead space ventilation (VD) is one of the important measurements that indicates the ventilatory efficiency of a patient who requires mechanical ventilation.